Vibration or displacement eddy current sensor, with straight or transverse cable output, and integrated or separate extension coaxial cable. The VF71 is used with the signal conditioner AO-01, The VF72 is used with the signal conditioner AO-02 

Relative vibration                           
• Displacement, Position
• Speed
• Phase reference
- Range: 2mm or  4mm                     
- Sensitivity: 10/(8V)/mm or 5V/mm
- Head tip diameter: 8mm or 16mm
- Metric or English thread
- Temperature: -30..+170°C[200°C]
- Protection: IP68
- Standard length coax. cable: 5.9m    


Long range eddy current sensor, with axial cable output, and integrated coaxial cable. The VF75 is used with the signal conditioner AO-05, the VF77 is used with the signal conditioner AO-07 

• Displacement, Position
• Differential Expansion
- Range: 10mm or 14mm                     
- Sensitivity: 2V/mm or 1.43V/mm
- Head tip diameter: 8mm or 16mm
- M20x1 Metric thread
- Temperature: -30..+150°C[200°C]
- Protection: IP68
- Standard length coax. cable: 5.9m 
                                                   


- Power supply: -24Vdc
- Supply current:  15mA                    
- Frequency range AO-01: 0..10 khz
- Short circuit protected
- Polarity protection 
- Temperature: 0..+70°C
- Steel case
- Insulated base plate
- Exi versions available
- Protection boxes available
  for 2,4,6 conditioners

                                                   


For direct mounting on already existing accesses or specially designed fixtures. Custom made mounting device/brackets avoid expensive machining. Double sensor assemblies with proximity probe and piezo-velocity sensor for absolute shaft measurements are also available. 

Relative vibration  
Absolute shaft vibration                
• Speed
• Phase reference                               
- Range: 2mm or  4mm                 
- Sensitivity: 10/(8V)/mm or 5V/mm
- Industrial triaxial connector types or
   integral cable types 
- Stainless steel bodies
- Ready to mount
- Replacement types for V30 and V40
  former generation sensor series
- Temperature: -30..+170°C[200°C]
- Protection: IP68
- Extension coax. cable: 5.0m    


Contactless displacement transducer, pendulum on collar type, based on an eddy current measurement system (probe), for machine (turbine) shaft / case differential expansion measurement and axial shaft position. A customised machined especially strong magnet foot is following the collar position.

Standard available types :
WL173[A] (22.5 mm range)
WL172[A] (45 mm range)
WLNx71[A] (+- 1.4 mm range),  single, double or triple measurement types

• Axial Shaft Position 
• Differential Expansion
- Collar: 7mm (wide collars  
                    available)   
- Sensitivity: 2V/mm or 1.43V/mm     
- Temperature: -30..+170°C[200°C]   
- Protection: IP68
- Airgap adjustment screws
- Standard length coax. cable: 5.9m


V23 velocimeters are electrodynamic transducers with a stainless steel or aluminium alloy body. Various connection types are available, such as FRB, LEMO, DEUTSCH and JUPITER connector socket or PG11 feedthrough.

Bearing vibration                           
- Range: 1500 µm pp                     
- Sensitivity: 36mV/mm/s rms
- Freq. Range 10..1000 Hz
- No external power source required
- Temperature: 200°C [300°C]
- Protection: IP67


The VV81K100 , VV81K500 and VV81L100 are accelerometers with internal integration circuit to produce an output relative to velocity. The piezo velocity sensors can reduce signal noise and strong high frequency components coming from other sources.  The VV81K100 and VV81K500 have a rugged design and run continuously and reliable in an industrial environment. The sensors are housed in hermetic sealed, stainless steel cases with an industrial connector for maximum protection from corrosive  and oxidising chemicals.  

Bearing Vibration 
• Case Vibration                        
- Range: 50/10 in/sec pk
- Sensitivity: 100 and 500mV/in/sec
- Freq. Range 1.5..7000 Hz
- ICP 4mA supply current
- Case isolated and shielded
- MIL-C-5015 connector
- Temperature: -50..+120°C
- Hermetically sealed
- Protection: IP68


Internally amplified high temperature accelerometers with isolated case and vertical vibration direction. The V81K100 and V81L100 are general purpose accelerometers that run continuously and reliable in an industrial environment. The sensors are housed in hermetic sealed, stainless steel cases with an industrial connector for maximum protection from corrosive  and oxidising chemicals.  

Bearing Vibration 
• Case Vibration                        
- Range: 50g pk
- Sensitivity: 100mV/g
- Freq. Range 0.5..15000 Hz
- ICP 4mA supply current
- Case isolated and shielded
- MIL-C-5015 connector
- Temperature: -50..+150°C
- Hermetically sealed
- Protection: IP68


Accelerometer sensor with integrated electronic impedance converter, ground isolated, high sensitivity, horizontal vibration direction. V82_100, V82_1000, V81GL/100 and V81GL/1000 types with Lemo connector. V81GJ/100 and V81GJ/1000 with Jupiter connector.

Bearing Vibration 
• Case Vibration                      
- Range: 5g pk or 50g pk
- Sensitivity: 1V/g or 100mV/g  
- Freq. Range 4..5000 Hz
- ICP 4mA supply current
- Case isolated and shielded
- Lemo or Jupiter connector
- Temp. Range: -50..+120°C
- Hermetically sealed
- Protection: IP67


The DD2,DD3,DD6 and DD8 pendulum transducers perform the measurement of the differential expansion on turbogenerators and similar rotating machines. The DD5 pendulum transducer performs the measurement of the shaft axial position. The
The basic principle of operation is a suspended magnet which follows a shaft collar displacement. The sensor element is a pair of accurate coils, measuring the displacement of a target plate. The slim and vertical design of a DD2 transducer allows its mounting on the machine at relatively narrow locations.The rugged design and the continuous further development of the transducers assures a reliable and accurate measurement over the life time of a machine.
Compared with other measurement systems, the pendulum transducer principle allows the translation of the measuring point to a more protected (steam leaks) and cooler area, which minimise also the temperature effect on the measurement.
Furthermore, the actual measurement is performed onto a target made of reference steel, avoiding measurement discrepancies due to various steel qualities, as may occur with direct measurements onto the shaft. Dedicated DD-transducer interfaces are standard in all CIS AMREIN monitoring systems.  

• Differential Expansion
Axial Shaft Position 
- Collar: 7mm (wide collars available)   
- Range DD2A/B/K:      15mm
- Range DD2C/G/F/H:   30mm
- Range DD3:              40/50mm
- Range DD5:              +- 1.4mm
- Range DD6:              60mm
- Range DD7:              +-1.4mm
- Accuracy 25°C:         < 0.5% FS
- Op. Temperature:  200°C
                            300°C (HT) 
                            400°C (IHT)   
- Protection: IP67
- Airgap adjustment screws
- Lemo or FRB industrial connector
   or integral cable


The BC2 and BC5 transducers are dual coil transducers for high collar applications. Dedicated BC-transducer interfaces are standard in all CIS AMREIN monitoring systems.  

• Differential Expansion                     
Axial Shaft Position 
- Range BC2:          < 30mm
- Range BC5:          < 20mm
- Accuracy 25°C:    < 1.5% FS
- Op. Temperature:  200°C
                            300°C (HT) 
- Protection: IP68
- Integral cable


The AD7 and AD9 inductive displacement transducer perform the measurement of absolute case expansion on turbogenerators and similar rotating machines.
The basic principle of operation is a fixed casing, whereas the feeler rod follows a case displacement up to 20mm or 50mm.The AD7 and AD9 are equipped with an integral display/scale. Dedicated AD-transducer interfaces are standard in all CIS AMREIN monitoring systems.  

• Absolute Case Expansion  
- Range AD7:          10/20mm
- Range AD9:          50mm
- Accuracy 25°C:    < 1.5% FS
- Op. Temperature:  200°C
                            300°C (HT) 
- Protection: IP65
- Lemo or FRB industrial connector     


Long-range displacement transducer with UNIBAL mounting rod ends, for steam turbine valve position measurement (or process inlet command), based on a LVDT (Linear Variable Differential Transformer) element, housed into a rugged assembly, with an industrial FRB or LEMO® HT plug-in connector.Dedicated WZ-transducer interfaces are standard in all CIS AMREIN monitoring systems.  

• Valve Position
- Range WZ:           32mm to 350mm
- Accuracy 25°C:    < 0.5% FS
- Op. Temperature:  120°C                   
- Protection: IP54
- Lemo or FRB industrial connector                           